Screen capture of LabVIEW program displaying detected RF level from ZX47-55 module. Program also provides mW and uW output levels. Module reads levels very quickly, with an average across 100 samples used for the display.
Screen capture showing program setup parameters, including turning on the +5V DC supply, and setup/init for the two scope channels used for RF Power and Temperature inputs.
Main loop for the program showing loop init, data capture and read output, conversion and formatting, and read DC supply output. Loop runs continuously until front panel stop button is pressed.
Screen capture of loop closeout functions (after stop button is pressed) which turns off +5V supply and closes out scope functions to allow a clean program start up thereafter.
@hamchallenge HC46S Write a useful computer program. Created SW interface to read a Mini-Circuits ZX47-55 RF Detector using an Digilent AD3 interface module. Used free LabVIEW Community Edition for programming environment. SW provides a nice stable readout of […]
[Original post on mastodon.radio]